Colorado Lighting Logo
contact link site map link home page Link

Customer Login
Service Order Request
Online Product Order

CLI HIGHLIGHTS

LIGHTING
INNOVATIONS

HELPFUL
MAINTENANCE STEPS

RECYCLING INFO


 

 

  • Most significant energy saving advancement in linear fluorescent technology in 25 years
  • Earth friendly: TCLP compliant and significantly lower energy consumption
  • Patent pending invention driven by a multi-million dollar GE research and manufacturing investment. Conserves energy without sacrificing life or light output
  • Performance assured through rigorous 6 sigma methodology
Ultra: Advanced lighting technology to yield significant energy savings!

F32T8 Watt-Miser


F32T8/SP/IS/WM/ECO

  • Uses 6% Less Energy compared to F32T8!*
  • Operates at 30 watts
  • Same Light Output and Life as
    F32T8/SP.**


Technology

- 94% Lumen Maintenance
- 81 CRI - industry best SP rating
- 2850 Initial Lumens

  • TCLP Compliant *

* -Energy savings are 5% on a 60 Hz reference ballast
** - Recommended for instant start electronic ballasts only

2 Watts/lamp Energy Savings Martix
Example Calculation Energy Savings Matrix
Operating Hours per year
Savings per lamp over life
KWH Rate 4000 5500 8760 20000


Actual savings will depend on current end-user system. Example shown is F32T8/SP/IS/WM/ECO vs. F32T8/SP for 12 hrs/start; 20k hrs life

Spot Relamping Savings -
 - Realize immediate energy savings with no performance loss

Group Relamping Savings -
 - Maximize Energy and Labor Savings


GE Electronic Ultra Watt-Miser® Ballast
Savings Per Ballast vs Comparable BF Ballast
5 Watts saved Energy Savings Matrix
Savings per ballast per year
Operating Hours/Year
Savings over lamp life
KWH Rate 4000 5500 8760 20000

4 lamp .78 BF IS system with F32T8/SP lamps

Improve Retrofit Payback

  • Specify GE Ultra Watt-Miser® Ballast for Planned Retrofits
  • Improve Return on Investment
  • Quick payback!
* F17 THD less than 15%.
The Ballast Advantage: Quicker Payback, Greater ROI vs Standard Systems

GE Ultra Watt-Miser® Lamp/Ballast System
  • 11% Energy Reduction Versus Comparable T8 Lamp/Ballast System
    (6% Lamps + 5% Ballast = 11%)
Savings Per Ultra Watt-Miser® Lamp/Ballast System
vs Comparable F32T8 System
11 Watts saved Energy Savings Matrix
System Savings per year
Operating Hours/Year
Savings over lamp life
KWH Rate 4000 5500 8760 20000

4 lamp .78 BF IS Ballast System
Ultra Watt-Miser® Systems Savings So Great...
The Competition Could Give Their Product Away and Still Not compare!

GE T8 Systems
Lamp/Ballast HI EFFICIENCY RAPID
START
LOWATT NORMAL ULTRA
NORMAL
ULTRA
LOWATT
Watt-Miser T12 (CW) Watts:
BF:
Light:
RPLW:
Life:
148
0.90
100%
100%
20K
Watts:
BF:
Light:
RPLW:
Life:
124
0.89
99%
118%
20K
F32T8 & F32T8/XL (SP) Watts:
BF:
Light:
RPLW:
Life:

138
0.88
116%
125%
20K/24K

Watts:
BF:
Light:
RPLW:
Life:
120
0.88
116%
143%
20K/24K
Watts:
BF:
Light:
RPLW:
Life:
101
0.78
103%
151%
15K/18K
Watts:
BF:
Light:
RPLW:
Life:
114
0.88
116%
151%
15K/18K
Watts:
BF:
Light:
RPLW:
Life:
107
0.88
116%
161%
15K/18K
Watts:
BF:
Light:
RPLW:
Life:
96
0.78
103%
159%
15K/18K
F32T8/WM ULTRA (SP) Watts:
BF:
Light:
RPLW:
Life:
95
0.78
102%
158%
15K
Watts:
BF:
Light:
RPLW:
Life:
107
0.88
115%
159%
15K
Watts:
BF:
Light:
RPLW:
Life:
101
0.88
115%
168%
15K
Watts:
BF:
Light:
RPLW:
Life:
89
0.78
102%
169%
15K
                       
  • GE System Warranty -
    - 3 Years Lamp*
    - 5 years Ballast
  • 11% Energy savings over comparable T8 system
  • 40% Energy savings over comparable T12/WM system!!!
Copyright © Colorado Lighting 2008