: Regulations & Codes : City & County Lighting Codes of Colorado : City of Thornton :

Section 18-391. Lighting.

Off-street parking for a use other than single-family or two-family uses that offers service after dark shall be lighting beginning one-half hour after sunset and continuing throughout the hours of use. If only a portion of the parking area is offered for use after dark, only that part shall be lighting. The lighting of the off-street parking area shall meet the following minimum requirements:

(1) The intensity of lighting on the parking surface shall be:

a. An average of at least one foot-candle, initial measurement; and

b. a minimum at any point of at least four-tenths foot-candle initial measurement. Requirements for maintenance of parking lot lighting shall include replacement of bulbs and light fixtures, regular cleaning, and replacement of light poles as needed.

(2) The light source shall be indirect, diffused or shielded type fixtures, installed to reduce glare and the consequent interference with boundary streets and adjacent property.

(3) Fixtures shall be attached to buildings or mounted on poles in such a manner and at such a height that light is not directed at a residential use.

(4) Maximum height of lights shall not exceed 35 feet.

 