Chapter
4—Design Requirements and Performance Standards
4-12-01 LIGHTING (General)
1. Position of Lighting
Facility: Lighting facilities shall be arranged and positioned
so that no direct light or reflection creates a nuisance or hazard
on any adjacent property or right-of-way. Exterior lighting shall be
compatible with that of adjacent properties.
2. Consideration of Pilots:
No lighting facility shall make it difficult for pilots to
distinguish airport lights from others, result in glare in the eyes
of the pilots using an aviation facility, impair visibility in the
vicinity of an aviation facility or, in any way create a hazard or
endanger the landing, take-off, or maneuvering of aircrafts
intending to use an aviation facility.
3. Lighting Fixtures:
All lighting fixtures shall be located so as to shield direct rays
from adjoining properties. Luminaries shall be of a low level,
indirect, diffused type and shall not exceed a height of greater
than twenty (20) feet above finished grade.
4. Upward Lighting:
Upward lighting for architectural, landscape or decorative purposes,
shall have at least ninety percent (90%) of the total distribution
pattern within the profile of the illuminated structure. Light
fixtures use to illuminate flags, statues, or any other object
mounted on a pole, pedestal, or platform, shall use a narrow cone
beam of light that will not extend beyond the illuminated object
4-11-02-07 LIGHTING (Off Road Parking)
Any
lighting used to illuminate required off-road parking areas shall be
arranged in conformance with the following:
1. Lights shall be shielded so
that directly emitted light shall not shine directly onto
surrounding properties;
2. Light shall be arranged so
that neither direct nor reflect light may create a traffic hazard
and no color light(s) may be used in a manner which would be
confused with traffic control devises;
3. No blinking, flashing,
rotating or otherwise animated lights shall be permitted except
temporary holiday lighting displays or safety devices required by
federal, state, county or local regulations;
4. The maximum lighting level
shall not exceed one (1.0) foot-candle for parking areas and twenty
(20.0) foot-candle in loading areas and unloading platforms; and
5. Light levels measured twenty
(20) feet beyond the property line shall not exceed one-tenth (0.1)
foot-candle as a direct result of on-site lighting.
Back
|